Communication
RS485, Modbus-RTU / DL/T645-2007
Ethernet, Modbus-TCP, 2nd communication, WiFi, LoRa and 4G optional
Display
128×128 dot-matrix LCD with white LED backlight
56×60 mm visible area with electrical parameter and power quality display
Rated U and l
66/115 V, 230/400 V, 277/480 V, 400/690 V
AC 1 A / 5 A
External CT Secondary Input
APM520 is a 96 mm panel-mounted multifunction network power meter designed for comprehensive electrical measurement, energy metering, demand monitoring and power quality analysis. It supports three-phase three-wire and three-phase four-wire systems and is suitable for industrial power distribution, data centers, photovoltaic systems, energy storage systems and other critical power monitoring applications.
Voltage & Current 0.2%
Active Power 0.5%
Reactive Power 1%
Active Energy Class 0.5S, Class 0.2S optional
45–65 Hz
Voltage and current unbalance
Voltage and current phase angle
Voltage and current THD
2nd–63rd individual harmonics
Voltage crest factor and current K-factor
Interharmonics, flicker and fault waveform recording optional
Active, reactive and apparent energy
Four-quadrant energy
Current and power demand
Maximum demand with timestamp
Maximum / minimum value recording
Multi-tariff energy optional
RS485 / Modbus-RTU
Ethernet / Modbus-TCP, 2nd communication, WiFi, LoRa, 4G optional
4DI + 2DO + 2 Energy Pulse Outputs
Additional 4DI + 2DO, 2-channel Analog Output optional
Relay Output AC 250V/3A, DC 30V/3A
4-channel NTC Temperature Measurement
1-channel Leakage Current Measurement
Optional
AC 85–265V / DC 100–350V
Power Consumption ≤15VA
Front Panel IP54
IP65 optional
Operating Temperature -25°C to +70°C
Storage Temperature -40°C to +85°C
Relative Humidity ≤95%, non-condensing
Altitude ≤2500m
| Parameter | Specification |
| Power Network | 3-phase 3-wire / 3-phase 4-wire |
| Display | 128×128 dot-matrix LCD, white LED backlight |
| Visible Area | 56 × 60 mm |
| Frequency | 45–65 Hz |
| Rated Voltage | AC 3×57.7/100V, 3×63.5/110V, 3×230/400V, 3×400/690V |
| Rated Current | AC 3×1(1.2)A / AC 3×5(6)A |
| Current Connection | External CT |
| Voltage / Current Accuracy | 0.2% |
| Harmonic Accuracy | 1% |
| Frequency Accuracy | ±0.02 Hz |
| Active Power Accuracy | 0.5% |
| Reactive Power Accuracy | 1% |
| Active Energy Accuracy | Class 0.5S; Class 0.2S optional |
| Switch Input | 4DI standard |
| Relay Output | 2DO; AC 250V/3A, DC 30V/3A |
| Energy Pulse Output | 2EP |
| Standard Communication | RS485 / Modbus-RTU / DL/T645-2007 |
| Optional Communication | Ethernet / Modbus-TCP, 2C, WiFi, LoRa, 4G |
| Auxiliary Power | AC 85–265V / DC 100–350V |
| Power Consumption | ≤15VA |
| Operating Temperature | -25°C to +70°C |
| Storage Temperature | -40°C to +85°C |
| Relative Humidity | ≤95%, non-condensing |
| Altitude | ≤2500m |
| Front Protection | IP54; IP65 optional |
| Panel Size | 96 × 96 mm |
| Housing Size | 86.5 × 86.5 mm |
| Depth | 77.8 mm |
| Cut-out Size | 88 × 88 mm |
| Function | APM520 |
| Full electrical parameter measurement | Standard |
| Four-quadrant energy / phase energy / apparent energy | Standard |
| Demand & maximum demand | Standard |
| Extreme value statistics | Standard |
| Voltage / current unbalance | Standard |
| Voltage / current phase angle | Standard |
| Voltage / current THD | Standard |
| 2nd–63rd individual harmonics | Standard |
| Voltage crest factor / current K-factor | Standard |
| Voltage & current waveform | Standard |
| Event record | Standard |
| Alarm record | Standard |
| 4DI + 2DO | Standard |
| 2 Energy Pulse Outputs | Standard |
| RS485 / Modbus-RTU | Standard |
| DL/T645-2007 | Standard |
| Ethernet / Modbus-TCP | Optional |
| Extended 2nd Communication (2C) | Optional |
| Additional 4DI + 2DO | Optional |
| 2-channel Analog Output | Optional |
| Multi-tariff Energy | Optional (F) |
| 4-channel NTC Temperature Measurement | Optional (T) |
| 1-channel Leakage Current Measurement | Optional (L) |
| Interharmonics / Flicker | Optional (S) |
| Fault Waveform Recording | Optional (S) |
| WiFi | Optional |
| LoRa | Optional |
| 4G | Optional |