head_banner_pro

AMC72L-E4/KC Multifunction Panel Power Meter

Application:

1) Multifunction three-phase power monitoring for low-voltage distribution systems
2) Measures voltage, current, active power, reactive power, apparent power, power factor and frequency
3) Supports four-quadrant energy metering, voltage/current unbalance monitoring and phase angle measurement
4) Suitable for switchgear, distribution cabinets, factories, commercial buildings and energy management systems

Basic Parameters:

1) Wiring: three-phase four-wire
2) Rated voltage: AC 3×57.7/100V or 3×220/380V
3) Rated current: AC 1A or 5A
4) Accuracy: voltage/current Class 0.2; active power Class 0.5; active energy Class 0.5; reactive power/energy Class 1.0
5) Communication: RS485 Modbus-RTU, baud rate 1200–38400bps
6) I/O: 2DI+2DO+1 energy pulse or 4DI+2DO
7) Auxiliary power: AC/DC 85–265V
8) Panel size: 75×75mm; cut-out size: 67×67mm


Information

Parameter

Function

Download

Characteristic

5

Communication

RS485 Communication
Modbus-RTU Protocol
Baud Rate: 1200–38400bps

6

Display
LCD Display
System Time Display
Parameter Setting and Control via Keys

7

Rated U and l
Three-phase Four-wire
Rated Voltage: AC 3×57.7V/100V, AC 3×220V/380V
Rated Current: AC 1A or 5A
Frequency: 45–65Hz
Voltage Overload: 1.2× continuous, 2× for 1s
Current Overload: 1.2× continuous, 10× for 1s

General

AMC72L-E4/KC is a 72-size panel-mounted multifunction power meter designed for electrical parameter measurement, energy metering and power monitoring in three-phase four-wire systems.It measures three-phase voltage and current, zero-sequence voltage and current, active power, reactive power, apparent power, power factor, frequency, voltage phase angle, voltage/current unbalance, forward and reverse power and four-quadrant energy.The meter is equipped with an LCD display, RS485 communication and configurable digital input/output functions, making it suitable for power distribution systems, industrial facilities, commercial buildings, SCADA systems and energy management systems.

Function

Accuracy

Voltage & Current: Class 0.2
Active Power: Class 0.5
Reactive Power: Class 1.0
Active Energy: Class 0.5
Reactive Energy: Class 1.0
Frequency: 0.05Hz

Frequency

45–65Hz

Power Quality

Voltage phase angle
Voltage unbalance
Current unbalance

Energy Measurement

Forward and reverse power
Four-quadrant energy metering

微信图片_20260818173824_55_48
微信图片_20260818173845_56_48

Communication

RS485
Modbus-RTU
Baud Rate: 1200–38400bps

Input & Output

2DI + 2DO + 1 Energy Pulse
or
4DI + 2DO

Switching Input

Dry contact input, built-in power supply

Relay Output

Normally open contact
AC 250V / 3A
DC 30V / 3A

Auxiliary Power Supply

AC/DC 85–265V
Power Consumption ≤10VA

Environment

Operating Temperature: -25°C to +65°C
Storage Temperature: -40°C to +80°C
Relative Humidity: ≤93%RH, non-condensing
Altitude: ≤2500m

Wiring

AMC72L-E4KC_Wiring

Installation

AMC72L-E4KC_Installation

Typical connection

8

  • Previous:
  • Next:

  • Item Parameter
    Wiring Three-phase Four-wire
    Frequency 45–65Hz
    Rated Voltage AC 3×57.7V/100V, AC 3×220V/380V
    Voltage Overload 1.2 times continuous; 2 times for 1s
    Voltage Consumption <0.5VA
    Rated Current AC 1A / 5A
    Current Overload 1.2 times continuous; 10 times for 1s
    Current Consumption <0.5VA
    Voltage Accuracy Class 0.2
    Current Accuracy Class 0.2
    Active Power Accuracy Class 0.5
    Active Energy Accuracy Class 0.5
    Reactive Power Accuracy Class 1.0
    Reactive Energy Accuracy Class 1.0
    Frequency Accuracy 0.05Hz
    Communication RS485
    Protocol Modbus-RTU
    Baud Rate 1200–38400bps
    Digital Input Dry Contact Input
    Relay Output Normally Open Contact
    Relay Contact Capacity AC 250V/3A, DC 30V/3A
    Energy Pulse Open-collector Optocoupler Output
    Pulse Constant 10000 imp/kWh, Settable
    Auxiliary Power AC/DC 85–265V
    Auxiliary Power Consumption ≤10VA
    Operating Temperature -25℃~+65℃
    Storage Temperature -40℃~+80℃
    Humidity ≤93%RH, Non-condensing
    Altitude ≤2500m
    Function Support
    Three-phase Voltage
    Zero-sequence Voltage
    Three-phase Current
    Zero-sequence Current
    Active Power
    Reactive Power
    Apparent Power
    Power Factor
    Frequency
    Voltage Phase Angle
    Voltage Unbalance
    Current Unbalance
    Forward / Reverse Power
    Four-quadrant Energy
    System Time Display
    RS485
    Modbus-RTU
    Digital Input
    Relay Output
    Energy Pulse Output Optional Configuration
    LCD Display
  • Write your message here and send it to us
    -->