head_banner_pro

ADL200N-CT Single Phase MID UL Energy Meter

●Measurement: Bi-directional Energy, Power, Current, Voltage and etc.

●Rated Voltage: 110~240Vac (direct connect).

●Rated Current: Optional 80A, 120A, 200A, 300A,AC (via paired CT).

●Communication: RS485 (MODBUS-RTU).

●Response Time: 100ms (current, voltage, power); 1.0s (energy).

●Standard&Certificate: CE; MID; UL.

 

 


Information

Parameter

Download

General

1111

      ADL series DIN-rail mounted multifunctional electric energy meter is an intelligent instrument mainly designed for new energy power generation systems such as photovoltaic grid-connected system, micro inverter system, energy storage system, AC coupling system, etc. The product has the advantages of high precision, small volume, high respondent speed and convenient installation. The product has the features of sampling, metering and monitoring power parameters, communicating with an inverter or an energy management system (EMS), realizing the functions of preventing reverse flow, regulating power generation, charging and discharging batteries according to real-time power and accumulated electric energy, and realizing bidirectional metering and household distributed photovoltaic energy management. 

Function

● Input voltage: 230VAC

● Input current:80A, 120A, 200A, 300A

● Response rate:≤100ms

● Installation:35mm Din-rail method

● Dimension(L*W*H):90*18*65mm

XSX06094

Wiring

2222
3333

Structure

1741326840051

Related Products

DTSD1352-C

Three-phase solar energy meter

ACR10R-DxxTE

Single-phase solar energy meter

ADL400N-CT

Three-phase solar energy meter

ADL200N-CT is a single-phase DIN-rail energy meter built for photovoltaic grid-connected, micro-inverter, storage and AC-coupling systems. Current comes from a split-core coil, so the live conductor is not cut, and the meter reports bidirectional energy to your inverter or EMS over RS485.

  • Rated voltage

    AC 230 V

  • Current input

    0.5-10(80) A / 0.5-10(120) A

  • Active energy

    Class B, EN 50470-3

  • Response

    100 ms or less

Technical data

Parameter Value (from the product manual)
GridSingle-phase, bidirectional metering
Rated voltageAC 230 V, input range +/-20%
Voltage overload1.2 x rated continuous; 2 x rated for 1 s; 2 W and 10 VA or less
Input currentAC 0.5-10(80) A or AC 0.5-10(120) A via split-core coil
Current overload / burden1.2 x rated continuous, 2 x rated for 1 s; 1 W and 1 VA or less
Measurement accuracyVoltage, current, power and frequency within +/-0.5%
Active energyClass B (EN 50470-3 index B)
Reactive energyClass 2 accuracy
Frequency50 / 60 Hz, within +/-0.5%
Response rate100 ms or less for voltage, current and power; 1 s or less for energy
Power consumption2 W or less
Safety classMeasurement category CAT III, overvoltage OVC III, protection class II (double insulation), pollution degree II
Withstand voltageAC 3 kV / 1 min between communication and signal input; coil 4000 V 50 Hz / 1 min
Insulation resistanceInput and output to case over 100 MOhm; coil over 1000 MOhm
CommunicationRS485, MODBUS-RTU, address 1-247
EMCClass E2
EnvironmentIP51 in a suitable IP-rated enclosure, indoor, cabinet mounted, mechanical class M1
Wiring2.5-10 mm2 (13-7 AWG) at 2 N m; 0.25-1.5 mm2 (26-16 AWG) at 0.5 N m
SealingSealing wire diameter 2 mm or less
Coil flame retardancyUL94-V0
Dimensions90 x 18 x 65 mm (1-module DIN rail body)
StandardsEN 50470-3, EN IEC 61010-2-030, EN IEC 61326-1, EN IEC 61326-2-1

Measured functions

Function ADL200N-CT
Electric energyActive energy forward and reverse; reactive energy forward and reverse
Electric quantityU, I, P, Q, S, PF, frequency
DisplaySegmented LCD
Pulse outputActive energy pulse
CommunicationRS485, Modbus-RTU

Built-in functions

  • Bidirectional metering for household distributed photovoltaic energy management
  • Talks to the inverter or EMS to support anti-backflow, generation regulation and battery charge control
  • Split-core coil installation without cutting the live conductor
  • High response speed, compact 18 mm rail body, no commissioning run needed
  • Address, baud and check bits configurable over the RS485 port

Before you request a quote

  • Maximum load current (80 A or 120 A coil range)
  • Conductor diameter at the installation point
  • Inverter or EMS protocol you need matched

The meter body must sit inside an enclosure that keeps the IP rating. Tell us the load current, conductor diameter and inverter brand, and we confirm the coil range, the register map and the anti-backflow wiring within one working day.


  • Previous:
  • Next:

  • 1. Technical parameter

    Item Performance Parameters
    Model Series ADL200N-CT ADL400N-CT
    Measurement Grid Single-phase Three-phase four-wire, three-phase three-wire, single-phase three-wire
    Voltage Rated voltage 230V Three-phase: 3×220/380V, 3×230/400V, 3×277/480V 
    Input Range ±20%
    Overload 1.2 times rating (continuous)2 times the rating for 1 second
    Power consumption <0.2VA
    Accuracy class Error ±0.5%
    Current Input current 80A, 120A, 200A, 300A 3×80A, 3×120A, 3×200A, 3×300A
    Overload 1.2 times rating (continuous)2 times the rating for 1 second
    Power consumption <0.2VA
    Accuracy class Error ±0.5%
    Power Active, reactive, apparent power, error ±0.5%
    Grid frequency 45~65Hz, error ±0.5%
    Response rate ≤100ms (voltage, current, power)
    ≤1s (electrical energy)
    Metering Electric energy Active energy : Class B (split current transformer)Reactive energy (Class 2 accuracy)
    Electromagnetic Compatibility Electrostatic discharge immunity class III
    Electrical fast transient burst immunity class IV
    Surge (shock) immunity Class IV
    Security Power frequency withstand voltage Between communication and signal input, AC4kV 1min
    Insulation resistance Input and output terminals to casing >100MΩ
    Communication Interface and communication protocol RS485 interface and Modbus RTU protocol
    Communication address range Modbus RTU: 1~ 247;
    Baud rate Support 1200bps-38400bps
    Environment Operating temperature -40℃~+70℃
    Storage temperature -40℃~+70℃
    Relative humidity ≤95% (without condensation)
    Altitude ≤3000m
    Write your message here and send it to us
    -->