Application:

1)Comprehensive three-phase power monitoring for distribution and energy management
2)Measures and records real-time demand and maximum demand for peak-demand analysis
3)Supports energy metering, harmonics, unbalance and other power quality monitoring
4)Suitable for factories, industrial parks, commercial buildings, data centers, PV/ESS systems and switchgear

Basic Parameters:

1)Demand: three-phase current plus active, reactive and apparent power
2)Rated input: 57.7/100 V, 63.5/110 V, 230/400 V, 400/690 V; 1 A or 5 A
3)Accuracy: voltage/current 0.2%; active power 0.5%; active energy Class 0.5S, optional 0.2S
4)Communication: RS485 Modbus-RTU / DL/T645; Ethernet and wireless communication optional
5)Size: 96 × 96 mm panel; 88 × 88 mm cut-out


Information

Parameter

Function

Download

Characteristic

5

Communication
RS485, Modbus-RTU / DL/T645-2007
Ethernet, Modbus-TCP, 2nd communication, WiFi, LoRa and 4G optional

6

Display
128×128 dot-matrix LCD with white LED backlight
56×60 mm visible area with electrical parameter and power quality display

7

Rated U and l

66/115 V, 230/400 V, 277/480 V, 400/690 V

AC 1 A / 5 A
External CT Secondary Input

General

APM520 is a 96 mm panel-mounted multifunction network power meter designed for comprehensive electrical measurement, energy metering, demand monitoring and power quality analysis. It supports three-phase three-wire and three-phase four-wire systems and is suitable for industrial power distribution, data centers, photovoltaic systems, energy storage systems and other critical power monitoring applications.

Function

Accuracy

Voltage & Current 0.2%
Active Power 0.5%
Reactive Power 1%
Active Energy Class 0.5S, Class 0.2S optional

Frequency

45–65 Hz

Power Quality

Voltage and current unbalance
Voltage and current phase angle
Voltage and current THD
2nd–63rd individual harmonics
Voltage crest factor and current K-factor
Interharmonics, flicker and fault waveform recording optional

Energy Measurement

Active, reactive and apparent energy
Four-quadrant energy
Current and power demand
Maximum demand with timestamp
Maximum / minimum value recording
Multi-tariff energy optional

XSX09937
XSX09935

Communication

RS485 / Modbus-RTU
Ethernet / Modbus-TCP, 2nd communication, WiFi, LoRa, 4G optional

Input & Output

4DI + 2DO + 2 Energy Pulse Outputs
Additional 4DI + 2DO, 2-channel Analog Output optional
Relay Output AC 250V/3A, DC 30V/3A

Extended Monitoring

4-channel NTC Temperature Measurement
1-channel Leakage Current Measurement
Optional

Auxiliary Power Supply

AC 85–265V / DC 100–350V
Power Consumption ≤15VA

Protection Degree

Front Panel IP54
IP65 optional

Environment

Operating Temperature -25°C to +70°C
Storage Temperature -40°C to +85°C
Relative Humidity ≤95%, non-condensing
Altitude ≤2500m

Wiring

APM520_Wiring

Installation

APM520_Installation

Typical connection

8

  • Previous:
  • Next:

  • Parameter Specification
    Power Network 3-phase 3-wire / 3-phase 4-wire
    Display 128×128 dot-matrix LCD, white LED backlight
    Visible Area 56 × 60 mm
    Frequency 45–65 Hz
    Rated Voltage AC 3×57.7/100V, 3×63.5/110V, 3×230/400V, 3×400/690V
    Rated Current AC 3×1(1.2)A / AC 3×5(6)A
    Current Connection External CT
    Voltage / Current Accuracy 0.2%
    Harmonic Accuracy 1%
    Frequency Accuracy ±0.02 Hz
    Active Power Accuracy 0.5%
    Reactive Power Accuracy 1%
    Active Energy Accuracy Class 0.5S; Class 0.2S optional
    Switch Input 4DI standard
    Relay Output 2DO; AC 250V/3A, DC 30V/3A
    Energy Pulse Output 2EP
    Standard Communication RS485 / Modbus-RTU / DL/T645-2007
    Optional Communication Ethernet / Modbus-TCP, 2C, WiFi, LoRa, 4G
    Auxiliary Power AC 85–265V / DC 100–350V
    Power Consumption ≤15VA
    Operating Temperature -25°C to +70°C
    Storage Temperature -40°C to +85°C
    Relative Humidity ≤95%, non-condensing
    Altitude ≤2500m
    Front Protection IP54; IP65 optional
    Panel Size 96 × 96 mm
    Housing Size 86.5 × 86.5 mm
    Depth 77.8 mm
    Cut-out Size 88 × 88 mm
    Function APM520
    Full electrical parameter measurement Standard
    Four-quadrant energy / phase energy / apparent energy Standard
    Demand & maximum demand Standard
    Extreme value statistics Standard
    Voltage / current unbalance Standard
    Voltage / current phase angle Standard
    Voltage / current THD Standard
    2nd–63rd individual harmonics Standard
    Voltage crest factor / current K-factor Standard
    Voltage & current waveform Standard
    Event record Standard
    Alarm record Standard
    4DI + 2DO Standard
    2 Energy Pulse Outputs Standard
    RS485 / Modbus-RTU Standard
    DL/T645-2007 Standard
    Ethernet / Modbus-TCP Optional
    Extended 2nd Communication (2C) Optional
    Additional 4DI + 2DO Optional
    2-channel Analog Output Optional
    Multi-tariff Energy Optional (F)
    4-channel NTC Temperature Measurement Optional (T)
    1-channel Leakage Current Measurement Optional (L)
    Interharmonics / Flicker Optional (S)
    Fault Waveform Recording Optional (S)
    WiFi Optional
    LoRa Optional
    4G Optional