Accuracy: Class 1
Frequency Range: 45-65HZ
Pulse output: Active pulse output and Reactive pulse output
Consumption: <0.5VA
Dimension(L*W*H)72*97.7*36mm
Installation: DIN 35mm
Starting current: 4%lb(1 class)
ADW210 series din-rail type multi-loop power meters are mainly used for measuring the full electric parameters of multiple three-phase circuits, Up to four three-phase loop current inputs can be connected simultaneously.It can measure voltage and current, power, power factor, phase angle, unbalance, harmonic and other parameters.
Mounting
DIN 35mm Starting current: 4%lb(1 class)
| Parameter | Value |
|---|---|
| Accuracy | Class 1 Frequency Range: 45-65HZ Pulse output: Active pulse output and Reactive pulse output Consumption: <0.5VA |
DIN-rail mounted. Send us the rated values of your circuit and the supply voltage; we confirm the ordering code, wiring diagram and register list within one working day.
| Auxiliary power | AC/DC 85~265V;consumption≤10VA; | |||
|
Input | Frequency | 45~65Hz; | ||
| Voltage | AC 3×220V/380V; | |||
| Overload: 1.2 times of rated value (continuous); 2 times of rated value / 1s; | ||||
| Power consumption:≤ 0.5VA; | ||||
| Current | AC 5A, 100A, 400A, 600A;(External opening transformer) | |||
| Overload: 1.2 times of rated value (continuous); 10 times of rated value / 1s; | ||||
| Power consumption:≤ 0.5VA; | ||||
| Measurement accuracy | Frequency 0.05Hz, voltage and current 0.5 level, active electric energy level 1, reactive electric energy level 2; | |||
| 2-31 times harmonic accuracy: ± 1%; | ||||
| Features | Pulse output | Output mode: optocoupler pulse with open collector; | ||
| Communication | RS485, Modbus-RTU;Baud rate 1200~38400; | |||
| Switching | Input | Dry contact input, Built in power supply; | ||
| Output | Output mode: Relay normally open contact output; contact rating: AC 250V/3A DC 30V/3A; | |||
1.2 Module technical parameters
|
Switching Module | Power | RJ45 interface, DC 12V, Power consumption≤1W; |
| Communication | RJ45 interface, Modbus-RTU;(Communication with the main Part) | |
| Switching input | Dry contact input, Built in power supply; | |
| Switching output | Output mode: Relay normally open contact output; contact rating: AC 250V/3A DC 30V/3A; | |
|
Temperature and leakage module | Power | RJ45 interface, DC 12V, Power consumption≤1W |
| Communication | RJ45 interface, Modbus-RTU;(Communication with the main Part) | |
| temperature measurement | -20~100℃; | |
| Leakage measurement | 10~3000mA; | |
| measurement accuracy | temperature ±2℃, Leakage1.0%; |
1.3 Other technical parameters
| Safety | Power frequency withstand voltage | >AC 2kV/1min; |
| Insulation resistance | >100MΩ; | |
| Environment | working temperature:-20℃~+60℃; Storage temperature:-40℃~+70 ℃; relative humidity:≤95% No condensation; Altitude:≤2500m; | |
| electromagnetic compatibility | Better than grade 3; | |
2.1 Basic & Optional Function
✔ Full electric parameter measurement of N(1,2,3,4) three-phase circuit, external current transformer;
✔ Monitoring three Phase Voltage/Current, Zero sequence Current, Frequency;
✔ Monitoring three Phase power, total power (active, reactive, apparent);
✔ Monitoring three Phase power-factor, totalpower-factor;
✔ Monitoring voltage, current phase angle, voltage/current degree of unbalance;
✔ Monitoring voltage, current total harmonic and 2-31 fractional harmonics;
✔ Record of voltage, current and power extremum of current month and last month;
✔ Maximum current, Maximum power demand and real time current, real time power demand;
✔ 200 event records, record the action of DI/DO;
✔ Support over-voltage, over-current, phase failure, DI linkage and other alarm output;
✔ 4 time zones 14 periods rate setting;
✔ Four quadrant electric energy,12-month multi rate electric energy;
✔ 31 days four quadrant and multi rate electric energy freezing, Positive and negative energy metering;
✔ 2 channel Switching inputs, 2 channel Switching outputs, RS485, Active pulse output(Switchable corresponding circuit).
2.2 Extened Function
The following auxiliary functions can be extended through its RJ45 interface:
✔ (MK) 12 channel Switching inputs+4 channel Switching outputs;
✔ (MTL) 12 channel external NTC temperature +4 channel residual current measurement (leakage current);
✔ (AWT100-2G) 2G Wireless Communication
✔ (AWT100-4G) 4G Wireless Communication
✔ (AWT100-NB) NB-IoT Wireless Communication
✔ (AWT100-LoRa) LoRa Wireless Communication
✔ (AWT100-LW) LoRaWAN Wireless Communication