head_banner_pro

DJSF1352-D DC Energy Meter for Charging Pile

●Intergrate shunt in the energy meter

●300A, 600A input & 1000VDC

●RS485(MODBUS-RTU)

●Accuracy class: Class 1


Information

Parameter

Download

General

    The DJSF1352-D rail-mounted DC power meter, specifically designed for DC charging piles, is capable of measuring voltage, current, power, and energy, among other parameters.

微信截图_20250522141726
微信截图_20250522141746

DJSF1352-D-360

DJSF1352-D-600

Function

√ Input voltage
    1000VDC

√ Input current
     360A, 600A

微信截图_20250516161941
微信截图_20250516162027
微信截图_20250522161057
微信截图_20250522161035
√ Installation
      35mm Din-rail method
 
√ Accessory
      Comes with shunt

Wiring

Related Products

DJSF1352-D is a DIN-rail DC energy meter for photovoltaic, energy storage, EV charging and DC distribution circuits. It measures voltage up to DC 1000 V with a shunt, records bidirectional energy and offers RS485 plus an energy pulse output.

  • Voltage input

    DC 0-1000 V

  • Accuracy

    0.5 class (360) / 1 class (600)

  • Current input

    shunt 100(360) A or 4-90(600) A

  • Comms

    RS485, Modbus-RTU / DL/T 645 / DL/T 698

Technical data

Parameter Value (from the product manual)
ModelsDJSF1352-D-360, DJSF1352-D-600
Voltage inputDC 0-1000 V
Current input-360: 100(360) A per GB/T 33708-2017
-600: 4-90(600) A per EN 50470-4
Accuracy class-360: class C (0.5); -600: class B (1)
Power consumptionVoltage circuit 0.2 VA or less, current circuit 0.1 VA or less
DisplaySegment LCD, class 1
Communication interface1 x RS485
Communication protocolModbus-RTU, DL/T 645-2007, DL/T 698, baud 1200-38400 bps
Pulse outputOne energy pulse; constant set in SYS to PLUS menu (100 = 100 imp/kWh)
Auxiliary supplyDC 9-36 V, 3 W or less
Withstand voltageSupply, signal input and other circuits 4.4 kV / 1 min
Impulse withstand voltage+/-12.8 kV
Insulation resistance40 MOhm or more
Average continuous operating time50000 h or more
Environment-40 to +70 C, 95% RH or less non-condensing, altitude 2000 m or less
Overall dimensions-360: 124.6 x 59.4 x 50 mm; -600: 105 x 115 x 65 mm
Terminal torqueM2 0.2 N m (comms, pulse, aux); M3 0.5 N m (voltage); M10 25 N m (shunt)
StandardsGB/T 33708-2017, GB/T 29318-2012, DL/T 645-2007, DL/T 698.45

Functions by model

Item DJSF1352-D-360 DJSF1352-D-600
Energy accuracy0.5 class (class C)1 class (class B)
Current range100(360) A4-90(600) A
Reference standardGB/T 33708-2017EN 50470-4
Case size124.6 x 59.4 x 50 mm105 x 115 x 65 mm

What it does

  • Bidirectional active energy for charge and discharge accounting
  • EV DC charging metering per GB/T 29318-2012 non-onboard charger requirement
  • Protocol auto-adaptation between Modbus-RTU, DL/T 645-2007 and DL/T 698
  • Energy pulse output for revenue-testing or a second data capture device
  • Wide temperature range down to -40 C for outdoor cabinets

Before you request a quote

  • Maximum and minimum load current (to size the shunt)
  • String or bus voltage, and whether energy is bidirectional
  • Which protocol your system expects

The meter measures current through an external shunt, so please state the load current together with the voltage. We then confirm the model, shunt rating, torque sequence and register list within one working day.

DJSF1352-Rn

Dual-channel DC energy meter

ACR10R-DxxTE

Single-phase solar energy meter

ADL200N-CT

Single-phase solar energy meter


  • Previous:
  • Next:

  • 1.Technical parameter

    Technical parameters

    Index

    Input

    Nominal value

    Voltage input

    Current input

    DC 0-1000V

    DJSF1352-D-360:100(360)A

    DJSF1352-D-600:4-90(600)A

    Power consumption

    Voltage: ≤0.2VA, current ≤0.1VA

    Accuracy class

    Class B(Class 1)

    Function

    Display

    segment LCD screen (LCD)

    Communication Interface

    RS485

    Communication protocol

    Modbus-RTU, DL/T 645-2007, DLT698

    Pulse output

    A second pulse output, a energy pulse output

    See the SYS->PLUS display in the meter menu settings. For example: The meter displays 100, which is 100imp/kWH

    Power Supply

    Voltage range

    DC 9—36V

    Power consumption

    ≤ 3W

    Power frequency withstand voltage

    Power supply/Signal input/Other circuits  4.4kV/1min

    Impulse withstand voltage

    ±6KV

    Insulation resistance

    ≥ 40M Ω

    Average barrier-free working hours

    ≥50000h

    Environment

    Temperature

    working temperature: -40 °C ~ +70 °C

    Storage temperature: -40℃~+70℃

    Humidity

    ≤95%RH, no condensation, no corrosive gas

    Altitude

    ≤2000m

    Write your message here and send it to us
    -->