✔ Rated Voltage: 220V AC
✔ Incoming Current: 5A
✔ Outcoming Current: 100A/20mA
✔ Frequency: 45 - 60Hz
✔ Installation: 35mm Din-rail
✔ Dimension: 194*124*88mm
✔ Bacific Function: 1 DO + 1 RS485
With the rapid development of data center, the energy consumption problems about the data center have become increasingly serious, etc.
System voltage
220V AC ✔ Incoming
Frequency
45 - 60Hz
Mounting
35mm Din-rail ✔
| Parameter | Value |
|---|---|
| Current | 5A ✔ Outcoming |
| Dimension | 194*124*88mm ✔ Bacific Function: 1 DO + 1 RS485 |
DIN-rail mounted. Send us the rated values of your circuit and the supply voltage; we confirm the ordering code, wiring diagram and register list within one working day.
| Type | AMC16MA | AMC16Z | AMC16MD | AMC16K | ||||||||
| Power distribution system | AC | DC | AC | |||||||||
| Measuring parameters | Busbar voltage, current, active power, reactive power, power factor, active energy and reactive energy | Busbar voltage, current, po wer and energy | - | |||||||||
| Busbar voltage | Rated | 220V AC | -48V DC/DC240V | |||||||||
| Measurement range | 40-400V AC | ±20%/40-400V DC | ||||||||||
| Overload | instantaneous voltage twice/30 seconds | |||||||||||
| Current circuit | Incoming line | CT | Secondary 5A | (50-2000)A/50mA (5V) | ||||||||
| Range | 0-10A | 0-120% | ||||||||||
| Outgoing line | CT | 100A/20mA | (50-2000) A/50mA (5V) | |||||||||
| Range | 0-120% | 0-120% | ||||||||||
| Overload | 1.2 times for continuous, and 10 times/5 seconds for instantaneous | |||||||||||
| Input frequency | 45 – 60Hz | / | ||||||||||
| Auxiliary power supply | AC85 – 265V/DC100V – 350V | DC48V±20%/ DC100V – 350V | AC85 – 265V/DC100V – 350V | |||||||||
| Measurement accuracy | Incoming line | 1.0 | 1.0 | - | ||||||||
| Outgoing line | 2.0 | 2.0 | ||||||||||
| Power consumption | 5VA | 5W | 5VA | |||||||||
| Insulation resistance | 100MΩ | |||||||||||
| Power frequency withstand voltage | Power supply/input/output and inter-portsAC 2kV/1min 50Hz | |||||||||||
| On-off output | 5A 250VAC/5A 30VDC | |||||||||||
| On-off input | None | 21-way wet nodes 1-way dry nodes | None | 38-way wet nodes 4-way dry nodes | ||||||||
| Communication | 2-Wire Modbus-RTU | |||||||||||
| Installation method | DIN35mm guide rail installation | |||||||||||
| Protection grade | IP20 | |||||||||||
| Pollution grade | 2 | |||||||||||
| Electromagnet ic compatibility | Antistatic interference | Level3 | ||||||||||
| Resistance to electrical fast transient | Level3 | |||||||||||
| Resistance to surge interference | Level3 | |||||||||||
| Environment | Temperature | Working: -15℃-+55℃ Storage: -25℃-+70℃ |
| Humidity | Relative humidity ≤93% | |
| Altitude | ≤2500m |
2.1 Function of Different IDC Module
| Type | Functional description | Optional functions |
| AMC16MA | Measure busbar voltage of 3-phase total incoming lines 2-way three-phase incoming line 36-way single-phase outgoing line (12-way three-phase) 1-way DO & 1-way RS485 communication. | 2C-duplex communication |
| AMC16MA H | Increase 2nd-15th sub-frequency harmonic and total harmonic of incoming line voltage, incoming line current and outgoing line current based on the function of AMC16MA | Dual-power supply may be required AC220V+DC48V |
| AMC16MD | Outgoing line for measurement of DC busbar voltage 42-way direct current, active energy 1-way DO & 1-way RS485 communication | |
| AMC16Z | Measure busbar voltage of 3-phase total incoming lines 1-way three-phase incoming line 21-way single-phase outgoing line (7-way three-phase) 1-way DO & 1-way RS485 communication 21-way active DI (AC220V) & 1-way reactive DI | – |
| AMC16ZH | Increase 2nd-15th sub frequency harmonic and total harmonic of incoming line voltage, incoming line current and outgoing line current based on the function of AMC16Z |
|
| AMC16ZH- U | Open measurement of outgoing line circuit voltage based on the function of AMC16ZH. |
|
| AMC16K | 38-way active on-off input (AC220V) 4-way reactive DI 1-way DO & 1-way RS485 communication | – |