✔ Rated Voltage: 220V AC
✔ Rated Current: 5A
✔ A+B dual three-phase AC incoming circuit
✔ 8 switching status inputs, 4 switching status outputs
✔ Installation: 35mm Din-rail
✔ Dimension: 180*90*45m
AMC100-ZA A+B 2 Channel AC Energy Meter For IDC
System voltage
220V AC ✔
Mounting
35mm Din-rail ✔
| Parameter | Value |
|---|---|
| Rated Current | 5A ✔ A+B dual three-phase AC incoming circuit ✔ 8 switching status inputs, 4 switching status outputs |
| Dimension | 180*90*45m |
DIN-rail mounted. Send us the rated values of your circuit and the supply voltage; we confirm the ordering code, wiring diagram and register list within one working day.
| Instrument model | AMC100-ZA | |
| Measurement parameters | Voltage, current, frequency, active power, reactive power, power factor, active energy, reactive energy, Zero-to-ground voltage, leakage current and zero sequence current, total harmonic content (THD), 2-63 harmonics, current and voltage unbalance, ambient temperature and humidity | |
| Bus voltage | Rated | 220VAC |
| Measuring range | ±20% | |
| Overload | Instantaneous voltage 2 times/sec | |
| Current incoming circuit | Rated | Secondary 5A |
| Range | 0~6A | |
| Overload | Continuous 1.2 times, instantaneous 10 times/sec | |
| Temperature and humidity | Temperature Range | -40℃~+99℃ |
| Humidity Range | 20%~90% | |
| Input frequency | AC45~65Hz | |
|
Measurement accuracy
| Incoming line | Voltage/current level 0.2, active power/energy level 0.5, reactive power/energy level 1 |
| Temperature | ±1℃ | |
| Humidity | ±5% | |
| Auxiliary power | AMC100-ZA: signal to take power (≤15W) AMC100-ZA-P220: 220V independent power supply AMC100-ZA-P24: DC 12-24V independent power supply | |
| Switch output | 4 channels 3A 250VAC/3A 30VDC | |
| Switch input | 8 dry nodes | |
| Communication | 1 isolated RS485/Modbus-RTU to the background system 1 RS485/Modbus-RTU to touch screen 1 RS485/Modbus-RTU connection downstream module Optional 1-channel Ethernet communication function | |
| Installation Method | DIN35mm rail or bottom plate installation | |
| Protection level | IP20 | |
| Pollution level | 2 | |
|
Security
| Insulation | The insulation resistance between all terminals and the conductive parts of the shell is not less than 100MΩ |
| Withstand voltage | A voltage and current signal//B voltage and current signal//switch output//isolated communication port//between other ports meet AC2kV 1min, switch input and other ports should meet AC0.5kV 1min, leakage current Should be less than 2mA, no breakdown or flashover phenomenon. | |
|
Electromagnetic compatibility
| Anti-static interference | Level 4 |
| Anti-electric fast transient burst | Level 3 | |
| Anti-surge interference | Level 4 | |
| Resistance to radio frequency electromagnetic field radiation | Level 3 | |
|
Environment
| Temperature | Work: -20℃~150℃ Storage: -25℃~70℃ |
| Humidity | Relative humidity≤93% | |
| Elevation | ≤2500m |
2.1 Function of Different IDC Module
| Module | Function Description |
| AMC100-ZA | Monitoring the full power parameters of the A+B dual three-phase AC incoming circuit, 8 switching status inputs, 4 switching status outputs, 2 leakage monitoring, 1 temperature and humidity detection, 3 RS485 communications |
| AMC100-FAK30 | Monitor the full power parameters and switch status of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication |
| AMC100-FAK48 | Monitor the full power parameters and switch status of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication |
| AMC100-FA30 | Monitor the full power parameters of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication |
| AMC100-FA48 | Monitor the full power parameters of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication |
| AMC100-KA30 | Wet contact, monitor the switching status of 30 branches A+B, 1 RS485 communication |
| AMC100-KA48 | Wet contact, monitor the switching status of 48 branches A+B, 1 RS485 communication |
| AMC100-KD30 | Dry contact, monitor the switching status of 30 branches A+B, 1 RS485 communication |
| AMC100-KD48 | Dry contact, monitor the switching status of 48 branches A+B, 1 RS485 communication |
| AMC100-FT30 | 1 way RS485 communication, 30 way temperature measurement |
| AMC100-FT48 | 1 way RS485 communication, 48 way temperature measurement |