head_banner_pro

ADL100-ET Din-rail single phase energy meter with external CT

●AC220V

● 10(60)A, 20(100)A

● RS485(MODBUS-RTU)

● Set parameters

● LCD display

● kWh Class 1

● DIN 35 mm


Information

Parameter

Function

Download

Characteristic

1

LCD Display

2

Function

3
4

Appearance

5

Dimension(mm)

6

Wiring

7
8

Direct access

9

Transformer access

Installation

10
15

Typical connection

11

Specifications

Input voltage Reference voltage AC 220V
Reference frequency 50Hz
Power consumption <10VA
Input current Basic current 10A,20A(External transformer)
Maximum current 60A,100A(External transformer)
Starting current 4‰Ib
Consumption <4VA (Maximum current)
Measurement performance Accuracy of measuring 1class
Range of measuring 000000.00~99999999kWh
Clock accuracy Error≤0.5s/d
Active pulse Pulse width 80±20ms
Pulse constant 1600imp/kWh, 800imp/kWH(corresponding to basic current), LED
Communication Interface RS485(A+, B-)
Connection mode Shielded twisted pair conductors
Protocol MODBUS-RTU
Outline (Length × Width × Height) 88mm×36mm×70mm
Temperature Work temperature -25℃~55℃
Storage Temperature -40℃~70℃
Relative humidity ≤95%(No condensation)
Altitude <2000m

Functions

Function Function description Function provide
Measurement of kWh Single-phase active kWh (positive and negative) ■
Measurement of electrical parameters Voltage, Current, Active power, Reactive power, Apparent power, Power factor and Frequency ■
LCD Display 8 bits section LCD display ■
Key programming 3 keys to set parameters like code, address, baud rate, multi-tariff and communication protocol ■
Pulse output Active energy pulse output ■
Multi-tariff Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates □F
Communication Communication interface: RS485, Communication protocol: MODBUS-RTU □C
Infrared communication ■

Need the user manual, a wiring diagram or a quotation for your project? Ask us — we reply within one working day.


  • Previous:
  • Next:

  • 1.Technical parameter

    1.1 Electrical performance

    Input voltage

    Reference voltage

    AC 220V

    Reference frequency

    50Hz

    Power consumption

    <10VA

    Input current

    Basic current

    10A,20A(External transformer)

    Maximum current

    60A,100A(External transformer)

    Starting current

    4‰Ib

    Consumption

    <4VA (Maximum current)

    Measurement performance

    Accuracy of measuring

    1class

    Range of measuring

    000000.00~99999999kWh

    Clock accuracy

    Error≤0.5s/d

    Active pulse

    Pulse width

    80±20ms

    Pulse constant

    1600imp/kWh, 800imp/kWH(corresponding to basic current), LED

    Communication

    Interface

    RS485(A+, B-)

    Connection mode

    Shielded twisted pair conductors

     

    Protocol

    MODBUS-RTU

    Outline (Length × Width × Height)

    88mm×36mm×70mm

    1.2 Work environment

    Temperature

    Work temperature

    -25℃~55℃

    Storage Temperature

    -40℃~70℃

    Relative humidity

    ≤95%(No condensation)

    Altitude

    <2000m

    2. Functional Characteristic

    2.1 Basic & Optional Function

    Function

    Function description

    Function provide

    Measurement of kWh

    Single-phase active kWh (positive and negative)

    ■

    Measurement of electrical parameters

    Voltage, Current, Active power, Reactive power, Apparent power, Power factor and Frequency

    ■

    LCD Display

    8 bits section LCD display

    ■

    Key programming

    3 keys to set parameters like code, address, baud rate, multi-tariff and communication protocol

    ■

    Pulse output

    Active energy pulse output

    ■

    Multi-tariff

    Adapt 4 time zones, 2 time interval lists, 14 time interval by day and 4 tariff rates

    □F

    Communication 

    Communication interface: RS485, Communication protocol: MODBUS-RTU

    □C

    Infrared communication

    ■

    ( ■:  means standard; □:  means optional)

    Write your message here and send it to us
    -->