head_banner_pro

ADL200W Single-Phase Wireless Energy Meter

Application:

(1) PV systems
(2) Energy storage systems
(3) Microinverter systems
(4) AC-coupled systems

Basic Parameters:

(1) Single-phase, 230V
(2) External CT input, 80A / 120A
(3) RS485 + Wi-Fi communication
(4) Modbus RTU / Modbus TCP / HTTP
(5) Bidirectional energy metering


Information

Parameter

Function

Download

Characteristic

5

Dual-Circuit Metering
Dual-Circuit Energy Metering
Forward & Reverse Energy Metering
Real-Time Power Monitoring

6

Compact 1P Design
Only 18mm Wide
1P DIN-Rail Design
Compact and Space-Saving

7

Wi-Fi & Fast Response
2.4GHz Wi-Fi Communication
Modbus TCP / HTTP
Power Response Time: 50ms

General

ADL200W is a single-phase wireless energy meter with external CTs, designed for PV, energy storage, microinverter and AC-coupled systems. It supports bidirectional energy metering, RS485 and Wi-Fi communication for inverter and EMS integration.

Function

Connection

Single-Phase

Voltage

Nominal Voltage: 230V
Input Range: 0.8Unom–1.2Unom

Current

External CT Input
D10: 80A
D16: 120A

Accuracy

Voltage: ±0.5%
Current: ±0.5%
Power: ±1.0%
Active Energy: Class 1 or B

DSC01025_clipped_rev_1
DSC01029_clipped_rev_1

Communication

RS485: Modbus RTU
Wi-Fi: Modbus TCP / HTTP
Wi-Fi Frequency Band: 2.4GHz
IEEE 802.11b/g/n

Response Rate

50ms (Power)

Environment

Operating Temperature: -25℃ to +55℃
Extreme Operating Temperature: -40℃ to +70℃
Storage Temperature: -40℃ to +85℃
Relative Humidity: ≤95%, Non-condensing
Altitude: ≤2000m

Protection

Installation Category: CAT III
Overvoltage Category: OVC III
Front: IP51
Overall: IP20
Protection Class: Class II
Pollution Degree: II

Wiring

adl200w_wiring

Installation

adl200w_installation

Typical connection

8

  • Previous:
  • Next:

  • Item Parameter
    Grid Single-phase
    Nominal Voltage 230V
    Voltage Input Range 0.8Unom–1.2Unom
    Voltage Overload 1.2× continuous; 2× for 1s
    Voltage Power Consumption <3W, <10VA
    Voltage Accuracy ±0.5%
    Minimum Current 0.3A
    Transitional Current 1.5A
    Basic Current 30A
    Maximum Current D10: 80A; D16: 120A
    Short-Time Overcurrent 20Imax, 0.5s
    Current Power Consumption <1W, <1VA
    Current Accuracy ±0.5%
    Power Accuracy ±1.0%
    Frequency 50Hz
    Frequency Accuracy ±0.5%
    Response Rate 50ms (Power)
    Active Energy Accuracy Class 1 or B
    RS485 Protocol Modbus RTU
    Communication Address 1–247
    Baud Rate 1200–38400bps
    Wi-Fi 2.4GHz, IEEE 802.11b/g/n
    Wi-Fi Protocol Modbus TCP / HTTP
    Operating Temperature -25℃ to +55℃
    Storage Temperature -40℃ to +85℃
    Relative Humidity ≤95%, Non-condensing
    Altitude ≤2000m
    IP Rating Front: IP51; Overall: IP20
    Protection Class Class II
    Function Description
    Active Energy Metering Forward and reverse active energy
    Reactive Energy Metering Forward and reverse reactive energy
    Electrical Measurement U, I, P, Q, S, PF, F
    RS485 Communication Modbus RTU
    Wi-Fi Communication Modbus TCP / HTTP, 2.4GHz, IEEE 802.11b/g/n
  • Write your message here and send it to us
    -->