ADL100-EY single phase pre-paid meters with intro-control, ADL300-EY three phase pre-paid meters with intro-control are used for calculating the single and three phase active energy respectively on the frequency of 50 Hz. The meter has functions of pre-paid, load controlling and RS485 communication etc. meet the related technical requirements of electronic power meter in the IEC62053-21, IEC62053-22 standards
Accuracy
kWh Class 1
Frequency
50/60HZ(Optional), Range: 45~65HZ
Auxiliary power supply(self supply)
220Vac(L-N), range: 154~264Vac
Pulse output
Pulse output kWh
Consumption
<4VA(Each phase)
Installation
DIN 35mm
Dimension(L*W*H)
72*88*70mm
Active pulse
Constant: 6400imp/kWh,400imp/kWh
Clock
≤0.5s/d
Starting current
0.04A
ADL100-EY single phase pre-paid meters with intro-control, ADL300-EY three phase pre-paid meters with intro-control are used for calculating the single and three phase active energy respectively on the frequency of 50 Hz. The meter has functions of pre-paid, load controlling and RS485 communication etc.
| Parameter | Value |
|---|
Ask us about this model. Send us the rated values of your circuit and the supply voltage; we confirm the ordering code, wiring diagram and register list within one working day.
| Technical parameter | ADL100-EY | ADL300-EY | |||
| Voltage | Reference voltage | 220V | 3×220/380V | ||
| Reference frequency | 50Hz | ||||
| Consumption | <4VA(Each phase) | ||||
| Current | Input current | 10(60)A | 1(6)A ,10(80)A | ||
| Starting current | Connect directly: 0.004 Ib, connect via CT: 0.002In | ||||
| Consumption | <4VA (Maximum current) | ||||
| Measurement performance | Accuracy of measuring | 1 Class | 0.5s Class | ||
| Clock accuracy | Error ≤0.5s/d | ||||
| Active pulse | Pulse width | 80ms±20ms | |||
| Pulse constant | 1600imp/kWh | 6400imp/kWh,400 imp/kWh | |||
| Communication | Interface | RS485(A+, B-) | |||
| Connection mode | Shielded twisted pair conductors | ||||
| Protocol | MODBUS-RTU | ||||
| Temperature range | Work temperature | -25℃~55℃ |
| Storage Temperature | -40℃~70℃ | |
| Relative humidity | ≤95%(No condensation) | |
| Altitude | <2000m | |
2.1 Basic & Optional Function
| Function name | Function Description | Function provide | ||
| ADL100-EY | ADL300-EY | |||
| Measurement of kWh | Total active energy kWh (positive and negative in total) | ■ | ||
| Measurement of electrical parameters | U, I , P, Q, S, PF, F | ■ | ||
| Pre-paid mode | Through RS485 communication prepaid recharge, data encryption | ■ | ||
| Control | Built-in high-capacity sub-holding relay to achieve load on-off control | ■ | ||
| LCD display | 8 bits section LCD display | ■ | ||
| Communication | Communication interface: RS485, Communication protocol: MODBUS-RTU | ■ | ||
| Multi-tariff | 4 tariff rates, 14 time interval by day | 4 tariff rates, 14 time interval by day | □F | |
■: means standard; □: means optional
| Function name | Function Description | Function provide | ||
| ADL100-EY | ADL300-EY | |||
| Measurement of kWh | Total active energy kWh (positive and negative in total) | ■ | ||
| Measurement of electrical parameters | U, I , P, Q, S, PF, F | ■ | ||
| Pre-paid mode | Through RS485 communication prepaid recharge, data encryption | ■ | ||
| Control | Built-in high-capacity sub-holding relay to achieve load on-off control | ■ | ||
| LCD display | 8 bits section LCD display | ■ | ||
| Communication | Communication interface: RS485, Communication protocol: MODBUS-RTU | ■ | ||
| Multi-tariff | 4 tariff rates, 14 time interval by day | 4 tariff rates, 14 time interval by day | □F | |