ob_start_detected

AC & DC Multi-Circuit Metering
AC: Up to 8 Three-Phase / 24 Single-Phase Circuits
DC: Up to 12 DC Branch Circuits
Comprehensive Monitoring
Voltage, Current, Power & Energy
Independent Multi-Circuit Measurement
Communication & Monitoring
RS485 (Modbus-RTU)
Alarm, I/O & Temperature Monitoring
AC Version: Up to 8 Three-Phase Circuits or 24 Single-Phase Circuits
DC Version: Up to 12 DC Branch Circuits
AC Measurement: Voltage, Current, Power, Power Factor, Frequency & Energy
DC Measurement: Total Voltage, Total Current, Total Power, Total Energy and Individual Branch Measurement
AC Current Input: External Current Transformer, xxxA/50mA
DC Current Input: 12-Channel Hall Sensor, 0–5V DC Input
Communication: RS485 (Modbus-RTU)
Digital Input / Output: Available on AC Models
Temperature Monitoring: NTC Temperature Measurement
Alarm: Voltage, Power Supply, Metering and System Fault Alarms
Data Storage: Historical Energy and Alarm Data
Installation: Standard 35mm DIN Rail
AC Version
Rated Voltage: AC 3×220V/380V
Current Input: AC xxxA/50mA
(External Current Transformer)
Frequency: 45–65Hz
Voltage / Current Accuracy: Class 0.5
Active Energy Accuracy: Class 1
Auxiliary Power: AC/DC 85–265V
Communication: RS485 (Modbus-RTU)
Optional Communication: 4G / MQTT
DC Version
Rated Voltage: DC -48V
Current Input: 12 Channels, DC 0–5V
(External Hall Sensors)
Analog Input: 1 Channel, DC 0–5V
Voltage / Current Accuracy: Class 0.5
Power Accuracy: Class 1.0
Auxiliary Power: DC -40V to -60V
Communication: RS485 (Modbus-RTU)
Hall Sensor Power Supply: ±12V
AC & DC Multi-Circuit Metering
Output
RS485 (Modbus-RTU) Digital Input / Output: Available on
Modbus-RTU into your EMS / SCADA
Output (optional)
4G / MQTT
Energy accuracy
Class 1
Current input
External Current Transformer, xxxA/50mA
| Parameter | Value |
|---|---|
| AC | Up to 8 Three-Phase / 24 Single-Phase Circuits |
| DC | Up to 12 DC Branch Circuits |
| AC Version | Up to 8 Three-Phase Circuits or 24 Single-Phase Circuits |
| DC Version | Up to 12 DC Branch Circuits |
| AC Measurement | Voltage, Current, Power, Power Factor, Frequency & Energy |
| DC Measurement | Total Voltage, Total Current, Total Power, Total Energy and Individual Branch Measurement AC |
| DC Current Input | 12-Channel Hall Sensor, 0–5V DC Input |
| AC Models Temperature Monitoring | NTC Temperature Measurement |
| Alarm | Voltage, Power Supply, Metering and System Fault Alarms |
| Data Storage | Historical Energy and Alarm Data |
| Installation | Standard 35mm DIN Rail |
| AC Version Rated Voltage | AC 3×220V/380V |
| Frequency | 45–65Hz |
| Voltage / Current Accuracy | Class 0.5 |
| Auxiliary power | AC/DC 85–265V |
| DC Version Rated Voltage | DC -48V |
| Analog Input | 1 Channel, DC 0–5V |
| Power accuracy | Class 1.0 |
| Hall Sensor Power Supply | ±12V |
DIN-rail mounted. Send us the rated values of your circuit and the supply voltage; we confirm the ordering code, wiring diagram and register list within one working day.