head_banner_pro

AMC200 AC/DC Multi-Circuit Energy Meter

Application:

A flexible multi-circuit metering platform for telecom base stations, data center distribution cabinets and industrial submetering. AC and DC versions are separate ordering models and must be selected according to the monitored system.
Basic Parameters:

AC models monitor up to eight three-phase circuits or twenty-four single-phase circuits at 3×220/380 VAC. DC models monitor twelve single-phase -48 VDC circuits through 5 V-secondary Hall sensors. All versions provide RS485 communication; AMC200L models add a local LCD.


Information

function

Parameter

Download

Characteristic

5

AC & DC Multi-Circuit Metering
AC: Up to 8 Three-Phase / 24 Single-Phase Circuits
DC: Up to 12 DC Branch Circuits

6

Comprehensive Monitoring
Voltage, Current, Power & Energy
Independent Multi-Circuit Measurement

7

Communication & Monitoring
RS485 (Modbus-RTU)
Alarm, I/O & Temperature Monitoring

Main Functions

AC Version: Up to 8 Three-Phase Circuits or 24 Single-Phase Circuits

DC Version: Up to 12 DC Branch Circuits

AC Measurement: Voltage, Current, Power, Power Factor, Frequency & Energy

DC Measurement: Total Voltage, Total Current, Total Power, Total Energy and Individual Branch Measurement

AC Current Input: External Current Transformer, xxxA/50mA

DC Current Input: 12-Channel Hall Sensor, 0–5V DC Input

Communication: RS485 (Modbus-RTU)

Digital Input / Output: Available on AC Models

Temperature Monitoring: NTC Temperature Measurement

Alarm: Voltage, Power Supply, Metering and System Fault Alarms

Data Storage: Historical Energy and Alarm Data

Installation: Standard 35mm DIN Rail

Main Parameters

AC Version

Rated Voltage: AC 3×220V/380V

Current Input: AC xxxA/50mA
(External Current Transformer)

Frequency: 45–65Hz

Voltage / Current Accuracy: Class 0.5

Active Energy Accuracy: Class 1

Auxiliary Power: AC/DC 85–265V

Communication: RS485 (Modbus-RTU)

Optional Communication: 4G / MQTT

01_AMC200L_AC_Angle_Display_Off

DC Version

Rated Voltage: DC -48V

Current Input: 12 Channels, DC 0–5V
(External Hall Sensors)

Analog Input: 1 Channel, DC 0–5V

Voltage / Current Accuracy: Class 0.5

Power Accuracy: Class 1.0

Auxiliary Power: DC -40V to -60V

Communication: RS485 (Modbus-RTU)

Hall Sensor Power Supply: ±12V

Dimension

01_AMC200_AC_Dimensions