AMC300L Panel-Mounted Multi-Circuit Power Meter

Application:

A panel-mounted multi-circuit meter for data center distribution cabinets, industrial switchboards and centralized AC submetering where a local display is required.
Basic Parameters:

AMC300L-4E3 and AMC300L-6E3 monitor four or six three-phase circuits, equivalent to up to twelve or eighteen single-phase circuits. The 96 × 96 mm front frame fits an 88 × 88 mm panel cutout and works with matched external RJ current transformers.


Information

Function

Download

Characteristic

AMC300L Characteristic

Multi-Circuit AC Metering
Up to 6 Three-Phase Circuits
or 18 Single-Phase Circuits

AMC300L Characteristic

Comprehensive Measurement
Voltage, Current, Power & Power Factor
Four-Quadrant Energy Metering

AMC300L Characteristic

Communication & I/O
RS485 (Modbus-RTU)
6 Digital Inputs & 2 Relay Outputs

Main Functions

Main Functions

Voltage Measurement: Phase Voltage and Line Voltage

Current Measurement: Three-Phase Current and Zero-Sequence Current

Power Measurement: Active Power, Reactive Power and Apparent Power

Power Factor: Phase Power Factor and Total Power Factor

Frequency: AC Frequency Measurement

Energy Metering: Forward & Reverse Active Energy, Four-Quadrant Reactive Energy

Multi-Circuit Metering: Up to 6 Three-Phase Circuits or 18 Single-Phase Circuits

Digital Input: 6 Channels
(4 Passive Inputs + 2 Active AC 220V Inputs)

Relay Output: 2 Channels

Temperature Measurement: 2-Channel NTC Temperature Measurement
(AMC300L-6E3)

Communication: RS485 (Modbus-RTU)

Alarm: Overvoltage, Overcurrent, Phase Failure and DI Linkage Alarm

Data Storage: Historical Energy Data and Alarm Information

Installation: Panel Mounted

Main Parameters

Rated Voltage: AC 3×220V/380V

Rated Current: AC 100A
(External Current Transformer)

Frequency: 45–65Hz

Voltage Accuracy: Class 0.5

Current Accuracy: Class 0.5

Active Energy Accuracy: Class 1

Auxiliary Power Supply: AC/DC 85–265V

 

01_AMC16-DETT_Product

Communication: RS485 (Modbus-RTU)

Baud Rate: 1200–38400 bps

Digital Input: 4 Passive + 2 Active Inputs

Relay Output: 2 Channels, AC 250V/3A or DC 30V/3A

Temperature Measurement: -20°C to +100°C, ±2°C
(AMC300L-6E3)

Working Temperature: -20°C to +60°C

Humidity: ≤95% RH, No Condensation

Altitude: ≤2500m

Installation: Panel Mounted, 88 × 88mm Cutout

Dimension

01_AMC16-DETT_Dimensions

Wiring

02_AMC16-DETT_Wiring

Multi-Circuit AC Metering Up to 6 Three-Phase Circuits or 18 Single-Phase Circuits

  • Output

    RS485 (Modbus-RTU)

    Modbus-RTU into your EMS / SCADA

  • System voltage

    AC 3×220V/380V

  • Voltage accuracy

    Class 0.5

  • Energy accuracy

    Class 1

  • Certification on file:
  • CE certification
  • LEC certification
  • LVD certification

Technical data

ParameterValue
Voltage MeasurementPhase Voltage and Line Voltage
Current MeasurementThree-Phase Current and Zero-Sequence Current
Power measurementActive Power, Reactive Power and Apparent Power
Power FactorPhase Power Factor and Total Power Factor
FrequencyAC Frequency Measurement
Energy meteringForward & Reverse Active Energy, Four-Quadrant Reactive Energy
Multi-circuitUp to 6 Three-Phase Circuits or 18 Single-Phase Circuits Digital Input: 6 Channels (4 Passive Inputs + 2 Active AC 220V Inputs) Relay Output: 2 Channels
Temperature Measurement2-Channel NTC Temperature Measurement (AMC300L-6E3)
AlarmOvervoltage, Overcurrent, Phase Failure and DI Linkage Alarm
Data StorageHistorical Energy Data and Alarm Information
InstallationPanel Mounted
Rated CurrentAC 100A (External Current Transformer)
Current accuracyClass 0.5
Auxiliary powerAC/DC 85–265V
Baud rate1200–38400 bps Digital Input: 4 Passive + 2 Active Inputs Relay Output: 2 Channels, AC 250V/3A or DC 30V/3A
Working temp.-20°C to +60°C
Humidity≤95% RH, No Condensation
Altitude≤2500m

Built-in functions

  • Comprehensive Measurement Voltage, Current, Power & Power Factor Four-Quadrant Energy Metering
  • Communication & I/O RS485 (Modbus-RTU) 6 Digital Inputs & 2 Relay Outputs

Standard 35 mm DIN rail mounting. Need a wiring diagram or a Modbus register list for your EMS? Ask us — we reply within one working day.