ADL400W Three-Phase Wireless Energy Meter

Application:

(1) PV systems
(2) Energy storage systems
(3) Microinverter systems
(4) AC-coupled systems

Basic Parameters:

(1) Three-phase four-wire, 3×230/400V
(2) External CT input, 80A / 120A
(3) RS485 + Wi-Fi communication
(4) Modbus RTU / Modbus TCP / HTTP
(5) Bidirectional and split-phase energy metering


Information

Parameter

Function

Download

Characteristic

5

Dual-Circuit Three-Phase Metering
Dual-Circuit Energy Metering
Three-Phase Four-Wire
Forward & Reverse Energy Metering

6

Compact 1P Design
Only 18mm Wide
1P DIN-Rail Design
Compact and Space-Saving

7

Wi-Fi & Fast Response
2.4GHz Wi-Fi Communication
Modbus TCP / HTTP
Power Response Time: 50ms

General

ADL400W is a three-phase wireless energy meter with external CTs, designed for PV, energy storage, microinverter and AC-coupled systems. It supports bidirectional energy metering, RS485 and Wi-Fi communication for inverter and EMS integration.

Function

Connection

Three-phase Four-wire

Voltage

Nominal Voltage: 3×230/400V
Input Range: 0.8Unom–1.2Unom
Overload: 1.2× rated value continuously; 2× rated value for 1s

Current

External CT Input
Imin: 0.3A
Itr: 1.5A
Ib: 30A
D10: 80A
D16: 120A
Short-time Overcurrent: 20Imax, 0.5s

Accuracy

Voltage: ±0.5%
Current: ±0.5%
Power: ±1.0%
Active Energy: Class 1 or B
Grid Frequency: 50Hz, error ±0.5%

Energy Metering

Forward and Reverse Active Energy
Forward and Reverse Reactive Energy
Split-Phase Energy

DSC01025_clipped_rev_1
DSC01029_clipped_rev_1

Communication

RS485: Modbus-RTU
Address: 1–247
Baud Rate: 1200–38400bps
Wi-Fi: Modbus-TCP / HTTP
Wi-Fi Frequency Band: 2.4GHz
IEEE 802.11b/g/n

Response Rate

50ms (Power)

Environment

Operating Temperature: -25°C to +55°C
Extreme Operating Temperature: -40°C to +70°C
Storage Temperature: -40°C to +85°C
Relative Humidity: ≤95%, non-condensing
Altitude: ≤2000m

Protection

Installation Category: CAT III
Overvoltage Category: OVC III
Front: IP51
Overall: IP20
Protection Class: Class II
Pollution Degree: II
UC Degree: III
Installation Environment: Indoor
Mechanical Class: M1

Wiring

adl200w_wiring

Installation

adl200w_installation

Typical connection

8

  • Previous:
  • Next:

  • Item Parameter
    Grid Three-phase four-wire
    Nominal Voltage 3×230/400V
    Voltage Input Range 0.8Unom–1.2Unom
    Voltage Overload 1.2× continuous; 2× for 1s
    Voltage Power Consumption <3W, <10VA
    Voltage Accuracy ±0.5%
    Minimum Current 0.3A
    Transitional Current 1.5A
    Basic Current 30A
    Maximum Current D10: 80A; D16: 120A
    Short-Time Overcurrent 20Imax, 0.5s
    Current Power Consumption <1W, <1VA
    Current Accuracy ±0.5%
    Power Accuracy ±1.0%
    Frequency 50Hz
    Frequency Accuracy ±0.5%
    Response Rate 50ms (Power)
    Active Energy Accuracy Class 1 or B
    RS485 Protocol Modbus RTU
    Communication Address 1–247
    Baud Rate 1200–38400bps
    Wi-Fi 2.4GHz, IEEE 802.11b/g/n
    Wi-Fi Protocol Modbus TCP / HTTP
    Operating Temperature -25℃ to +55℃
    Storage Temperature -40℃ to +85℃
    Relative Humidity ≤95%, Non-condensing
    Altitude ≤2000m
    IP Rating Front: IP51; Overall: IP20
    Protection Class Class II
    Function Description
    Active Energy Metering Forward and reverse active energy
    Reactive Energy Metering Forward and reverse reactive energy
    Split-Phase Energy Supports split-phase energy metering
    Electrical Measurement U, I, P, Q, S, PF, F
    RS485 Communication Modbus RTU
    Wi-Fi Communication Modbus TCP / HTTP, 2.4GHz, IEEE 802.11b/g/n