head_banner_pro

AMC16Z-ZA A+B 2 Channel AC energy meter for IDC

● Designed specifically for the power supply management of server in the data center

● A+B independent 2 channels three-phase inlet

● U, I, P, Q, S, PF, kWh, kvarh

● 2nd-63rd Harmonic


Information

Parameter

Function

Download

Characteristic

1

Function

2
3

Appearance

4

Wiring

5
6

Typical connection

7
8
9

Specifications

Instrument model AMC16Z-ZA
Measured parameters Voltage, current, frequency, active power, reactive power, power factor, active power, reactive power
Zero ground voltage, neutral line current, total harmonic content (THD), 2-63 harmonics, current and voltage unbalance degree, current K coefficient (KF), voltage crest coefficient (CF), telephone waveform factor (THFF), peak voltage, voltage and current sequence quantity, environmental temperature and humidity.
Busbar voltage Rated 220VAC
Measurement ±20%
Overload Instant voltage 2times/second
Current incoming circuit Rated Twice 5A
Range 0~6A
Overload Duration 1.2 times, instantaneous 10 times/second
Temp &humidity Temp range -40℃~+99℃
humidity range 20%~90%
Input frequency 45~60Hz
Measurement precision Inlet wire Voltage/current level 0.2, active power/electric energy level 0.5, reactive power/electric energy level 1
Temp ±1℃
Humidity ±5%
Auxiliary power supply Take electric signal(≤15W)
Switch output 2-way 3A 250VAC/3A 30VDC
Switch input 6-way dry contact
Communication RS485/Modbus-RTU
Installation method DIN35mm Guide rail or bottom plate mounting
IP grade IP20
Class of pollution 2
Safety Insulation All terminals and the insulation resistance between the conductive pieces not less than 100MΩ
Withstand voltage A-way voltage and current signal, B-way voltage and current signal, switch output and other ports should meet AC2kV 1min in pairs, the switch input and other ports should meet ac0.5kv 1mim, leakage current should be less than 2mA, no breakdown or flashover
Electromagnetic compatibility Anti static interference Level 4
Electrical fast transient pulse group Level 3
Anti-surge interference Level 4
Resistance to radiation of Radio frequency electromagnetic field Level 3
EnvironmenT Temp Working:-15℃~55℃ Storage:-25℃~70℃
Humidity Relative humidity ≤93%
Altitude ≤2500m

Functions

Type Model Function description
AMC16Z-ZA Monitor the full power parameters of A+B double-way three-phase AC incoming circuit, 6-way switch state monitoring, 2-way alarm output, 2-way leakage monitoring, 1-way temperature and humidity detection, 1-way RS485 communication, and phase-sequence detection.
AMC16Z-FA Monitor the full power parameters of 24 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase adjustment.
AMC16Z-FAK24 Monitor the full power parameters and switch state of 24 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase adjustment.
AMC16Z-FAK48 Monitor the full power parameters and switch state of 48 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase adjustment.
AMC16Z-KA Wet contact, monitoring A+B total 48 branch switch state, 1-way RS485 communication.
AMC16Z-KD Dry contact, monitoring A+B total 48 branch switch state, 1-way RS485 communication.

Need the user manual, a wiring diagram or a quotation for your project? Ask us — we reply within one working day.


  • Previous:
  • Next:

  • 1.Technical parameter

    1.1 Electrical performance

    Instrument model

    AMC16Z-ZA

    Measured parameters

    Voltage, current, frequency, active power, reactive power, power factor, active power, reactive power

    Zero ground voltage, neutral line current, total harmonic content (THD), 2-63 harmonics, current and voltage unbalance degree, current K coefficient (KF), voltage crest coefficient (CF), telephone waveform factor (THFF), peak voltage, voltage and current sequence quantity, environmental temperature and humidity.

    Busbar voltage

    Rated

    220VAC

    Measurement

    ±20%

    Overload

    Instant voltage 2times/second

    Current incoming circuit

    Rated

    Twice 5A

    Range

    0~6A

    Overload

    Duration 1.2 times, instantaneous 10 times/second

    Temp &humidity

    Temp range

    -40℃~+99℃

    humidity range

    20%~90%

    Input frequency

    45~60Hz

    Measurement precision

    Inlet wire

    Voltage/current level 0.2, active power/electric energy level 0.5, reactive power/electric energy level 1

    Temp

    ±1℃

    Humidity

    ±5%

    Auxiliary power supply

    Take electric signal(≤15W)

    Switch output

    2-way 3A 250VAC/3A 30VDC

    Switch input

    6-way dry contact

    Communication

    RS485/Modbus-RTU

    Installation method

    DIN35mm Guide rail or bottom plate mounting

    IP grade

    IP20

    Class of pollution

    2

    Safety

    Insulation

    All terminals and the insulation resistance between the conductive pieces not less than 100MΩ

    Withstand voltage

    A-way voltage and current signal, B-way voltage and current signal, switch output and other ports should meet AC2kV 1min in pairs, the switch input and other ports should meet ac0.5kv 1mim, leakage  current should be less than 2mA, no breakdown or flashover

    Electromagnetic compatibility

    Anti static interference

    Level 4

    Electrical fast transient pulse group

    Level 3

    Anti-surge interference

    Level 4

    Resistance to radiation of Radio frequency electromagnetic field

    Level 3

    1.2 Work environment

    EnvironmenT 

    Temp

    Working:-15℃~55℃ Storage:-25℃~70℃

    Humidity

    Relative humidity ≤93%

    Altitude

    ≤2500m

    2. Functional Characteristic

    2.1 Function of Different IDC Module

    Type Model

    Function description

    AMC16Z-ZA

    Monitor the full power parameters of A+B double-way three-phase AC incoming circuit, 6-way switch state monitoring, 2-way alarm output, 2-way leakage monitoring, 1-way temperature and humidity detection, 1-way RS485 communication, and phase-sequence detection.

    AMC16Z-FA

    Monitor the full power parameters of 24 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase adjustment.

    AMC16Z-FAK24

    Monitor the full power parameters and switch state of 24 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase adjustment.

    AMC16Z-FAK48

    Monitor the full power parameters and switch state of 48 branches of A+B double-way AC outgoing line, 1-way RS485 communication and phase adjustment.

    AMC16Z-KA

    Wet contact, monitoring A+B total 48 branch switch state, 1-way RS485 communication.

    AMC16Z-KD

    Dry contact, monitoring A+B total 48 branch switch state, 1-way RS485 communication.

    Write your message here and send it to us
    -->