✔ 144mm & 180mm two versions
✔ Monitor the full power parameters of a total of 30/48 branches of A+B dual AC outlets
✔ 1 RS485 communication
Installation:
DIN-rail 35mm
CT installation:
Pluggable CT connector
| Definition | Illustrate | Remark |
| V+ | Auxiliary power | Powered by AMC100-ZA Or powered by DC12-24V power supply |
| V- | ||
| A | RS485 |
Connect the pre-module
|
| B |
| A1-A24 | Route A current input | circuit A outgoing line AC current input(24 channels) |
| B1-B24 | Route B current input | circuit A outgoing line AC current input(24 channels) |
✔ 144mm & 180mm two versions ✔ Monitor the full power parameters of a total of 30/48 branches of A+B dual AC outlets ✔ 1 RS485 communication
Mounting
DIN-rail 35mm CT installation: Pluggable CT connector
| Parameter | Value |
|---|
DIN-rail mounted. Send us the rated values of your circuit and the supply voltage; we confirm the ordering code, wiring diagram and register list within one working day.
| Instrument model | AMC100-FA30 | AMC100-FA48 | |
| Measurement parameters | Voltage, current, frequency, active power, reactive power, power factor, active energy, reactive energy, 2-31 times total current harmonic content | ||
| Bus voltage | Rated | 220VAC | |
| Measuring range | ±20% | ||
| Overload | Instantaneous voltage 2 times/sec | ||
| Current outlet loop | Rated | 50mA | |
| Range | 0.125~60mA | ||
| Overload | Continuous 1.2 times, instantaneous 10 times/sec | ||
| Input frequency | AC45~65Hz | ||
| Measure | Outlet | Voltage/current/active power/active energy level 0.5, reactive power/reactive energy level 1 | |
| Auxiliary power | Powered by AMC100-ZA; DC 12-24V power supply when used alone | ||
| Communication | RS485/Modbus-RTU | ||
| Installation Method | DIN35mm rail or bottom plate installation | ||
| Protection level | IP20 | ||
| Pollution level | 2 | ||
|
Security
| Insulation | The insulation resistance between all terminals and the conductive parts of the shell is not less than 100MΩ | |
| Withstand voltage | The voltage and current signals of circuit A//the voltage and current signals of circuit B//other ports meet AC2kV for 1min, the leakage current should be less than 2mA, and there is no breakdown or flashover. | ||
| Electromagnetic compatibility | Anti-static interference | Level 4 | |
| Resistance to radio frequency electromagnetic field radiation | Level 3 | ||
| Environment | Temperature | Work: -15℃~55℃ Storage: -25℃~70℃ |
| Humidity | Relative humidity≤93% | |
| elevation | ≤2500m |
2.1 Function of Different IDC Module
| Model | Function Description |
| AMC100-ZA | Monitoring the full power parameters of the A+B dual three-phase AC incoming circuit, 8 switching status inputs, 4 switching status outputs, 2 leakage monitoring, 1 temperature and humidity detection, 3 RS485 communications |
| AMC100-FAK30 | Monitor the full power parameters and switch status of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication |
| AMC100-FAK48 | Monitor the full power parameters and switch status of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication |
| AMC100-FA30 | Monitor the full power parameters of a total of 30 branches of A+B dual AC outlets, and 1 RS485 communication |
| AMC100-FA48 | Monitor the full power parameters of a total of 48 branches of A+B dual AC outlets, and 1 RS485 communication |
| AMC100-KA30 | Wet contact, monitor the switching status of 30 branches A+B, 1 RS485 communication |
| AMC100-KA48 | Wet contact, monitor the switching status of 48 branches A+B, 1 RS485 communication |
| AMC100-KD30 | Dry contact, monitor the switching status of 30 branches A+B, 1 RS485 communication |
| AMC100-KD48 | Dry contact, monitor the switching status of 48 branches A+B, 1 RS485 communication |
| AMC100-FT30 | 1 way RS485 communication, 30 way temperature measurement |
| AMC100-FT48 | 1 way RS485 communication, 48 way temperature measurement |