Multi-Circuit Metering
Up to 12 Three-Phase Circuits
Communication
RS485 (Modbus-RTU)
Optional 4G / WiFi / Ethernet
Modular Design
Voltage, Current, I/O,
Temperature & Residual Current Modules
Measurement ①: U, I, P, Q, S, PF, F
Measurement ②: Forward & Reverse Active Energy, Four-Quadrant Reactive Energy
Multi-Circuit: Independent Multi-Circuit Energy Metering
Harmonics: Total Harmonic & 2nd–31st Harmonics
Communication: RS485 (MODBUS-RTU)
Wireless / Network Communication: Optional 4G / WiFi / Ethernet
I/O Extension: Optional 4DI / 2DO
Temperature Monitoring: Optional 12-Channel Temperature Measurement
Residual Current: Optional 4-Channel Residual Current Measurement
Installation: 35mm DIN Rail
Rated Voltage: 3×57.7/100V, 3×220/380V, 3×100V, 3×380V
Input Current:
D10: 0.03–0.15(6)A
D16: 0.8–2(100)A
D24: 3.2–8(400)A
D36: 4.8–12(600)A
Frequency: 45–65Hz
Voltage Accuracy: ±0.5%
Active Energy Accuracy: Class B
Communication: RS485 (MODBUS-RTU)
Optional Communication: 4G / WiFi / Ethernet
Working Temperature: -25°C to +55°C
Humidity: ≤95% RH, No Condensation
Altitude: <2000m
Installation: Standard 35mm DIN Rail
Multi-Circuit Metering Up to 12 Three-Phase Circuits
Output
RS485 (MODBUS-RTU) Wireless / Network
Modbus-RTU into your EMS / SCADA
Output (optional)
4G / WiFi / Ethernet
System voltage
3×57.7/100V, 3×220/380V, 3×100V, 3×380V
Voltage accuracy
±0.5%
| Parameter | Value |
|---|---|
| Measurement ① | U, I, P, Q, S, PF, F |
| Measurement ② | Forward & Reverse Active Energy, Four-Quadrant Reactive Energy |
| Multi-circuit | Independent Multi-Circuit Energy Metering |
| Harmonics | Total Harmonic & 2nd–31st Harmonics |
| Temperature Monitoring | Optional 12-Channel Temperature Measurement Residual |
| Current | Optional 4-Channel Residual Current Measurement |
| Installation | 35mm DIN Rail |
| Input current | D10: 0.03–0.15(6)A D16: 0.8–2(100)A D24: 3.2–8(400)A D36: 4.8–12(600)A |
| Frequency | 45–65Hz |
| Active energy accuracy | Class B |
| Working temp. | -25°C to +55°C |
| Humidity | ≤95% RH, No Condensation Altitude: <2000m |
DIN-rail mounted; communication wireless M-Bus / RF. Send us the rated values of your circuit and the supply voltage; we confirm the ordering code, wiring diagram and register list within one working day.
| ADW600 main function by module | |
| ADW600-M | Data collection and remote transmission over 4G, Ethernet or WiFi |
| ADW600-U | Voltage measurement and sampling |
| ADW600-I | Active energy metering (positive, reverse) and quadrant reactive energy; voltage, current, power factor, frequency, active, reactive and apparent power; total harmonic content and 2nd to 31st sub-harmonics; pulse output of active energy |
| ADW600-K | 4 digital inputs and 2 digital outputs |
| ADW600-TL | 12 channels of temperature measurement and 4 channels of residual current measurement |
| Electrical characteristics | |
| ADW600-U rated voltage | 3×57.7/100 V, 3×220/380 V, 3×100 V, 3×380 V |
| Voltage accuracy | 0.5% |
| Frequency range | 45-65 Hz |
| Voltage power consumption | <0.5 VA per phase |
| ADW600-I input current | D10 0.03-0.15(6) A; D16 0.8-2(100) A; D24 3.2-8(400) A; D36 4.8-12(600) A |
| Active energy accuracy | B class |
| Energy pulse width | 80 +/- 20 ms |
| Active energy pulse constant | D10 6400 imp/kWh; D16 400 imp/kWh; D24 100 imp/kWh; D36 60 imp/kWh |
| Current power consumption | <1 VA per phase |
| ADW600-K digital input | 4-channel passive input with built-in DC12 V power supply |
| ADW600-K digital output | 2-channel passive output, capacity AC230 V / DC30 V, 3 A |