DTSD1352-4S DIN-Rail Multi-Circuit Power Meter

Application:

A compact DIN-rail multi-circuit meter for telecom base stations, industrial distribution panels and AC submetering systems that require detailed energy, demand, power-quality and event data.
Basic Parameters:

DTSD1352-4S monitors four three-phase circuits or twelve single-phase circuits at 3×220/380 VAC through external 50 mA-secondary current transformers. It combines RS485 Modbus-RTU communication with harmonics, demand, multi-tariff, event and frozen-data functions.


Information

Parameter

Download

Characteristic

DTSD1352-4S Characteristic

Multi-Circuit Metering
Up to 4 Three-Phase Circuits
or 12 Single-Phase Circuits

DTSD1352-4S Characteristic

Communication
RS485 (Modbus-RTU)
Optional Ethernet Communication

DTSD1352-4S Characteristic

Modular Design
Voltage, Current, Power & Power Factor
Phase Angle, Unbalance & Harmonics

Main Functions

01_DTSD1352-4S_Front

Measurement ①: U, I, P, Q, S, PF, F

Measurement ②: Phase Angle, Voltage/Current Unbalance

Energy Metering: Forward & Reverse Active Energy, Four-Quadrant Reactive Energy

Multi-Circuit: Up to 4 Three-Phase Circuits or 12 Single-Phase Circuits

Harmonics: Total Harmonic Distortion & 2nd–31st Harmonics

Demand: Current Demand, Power Demand & Maximum Demand

Communication: RS485 (Modbus-RTU)

Energy Statistics: Multi-Rate Energy Statistics & Energy Freeze

Event Recording: Up to 200 Event Records

Alarm: Overvoltage, Overcurrent, Phase Failure and DI Linkage Alarm

Installation: 35 mm DIN Rail

Main Parameters

Auxiliary Power: AC/DC 85–265V or DC 40–60V

Rated Voltage: AC 3×220V/380V

Input Current: 50mA / 100mV / 333mV Optional
(External Current Sensor Required)

Frequency: 45–65Hz

Voltage & Current Accuracy: Class 0.5

Active Energy Accuracy: Class 1

Reactive Energy Accuracy: Class 2

Harmonics Accuracy: ±1% for 2nd–31st Harmonics

01_ADW600_Complete_System_Front (1)
04_DTSD1352-4S_Detail

Communication: RS485 (Modbus-RTU)

Optional Communication: Ethernet (Modbus TCP)

Baud Rate: 1200–38400 bps

Working Temperature: -25°C to +55°C

Humidity: ≤95% RH, No Condensation

Installation: Standard 35mm DIN Rail

Dimension

01_DTSD1352-4S_Dimensions_and_Terminals

Wiring

02_DTSD1352-4S_3P4W_Wiring
03_DTSD1352-4S_3P3W_and_1P_Wiring

Multi-Circuit Metering Up to 4 Three-Phase Circuits or 12 Single-Phase Circuits

  • Output

    RS485 (Modbus-RTU)

    Modbus-RTU into your EMS / SCADA

  • Output (optional)

    Ethernet (Modbus TCP)

  • System voltage

    AC 3×220V/380V

  • Accuracy

    Class 0.5

    Voltage & current

Technical data

ParameterValue
Measurement ①U, I, P, Q, S, PF, F
Measurement ②Phase Angle, Voltage/Current Unbalance
Energy meteringForward & Reverse Active Energy, Four-Quadrant Reactive Energy
Multi-circuitUp to 4 Three-Phase Circuits or 12 Single-Phase Circuits
HarmonicsTotal Harmonic Distortion & 2nd–31st Harmonics
DemandCurrent Demand, Power Demand & Maximum Demand
Energy statisticsMulti-Rate Energy Statistics & Energy Freeze
Event recordingUp to 200 Event Records
AlarmOvervoltage, Overcurrent, Phase Failure and DI Linkage Alarm
Installation35 mm DIN Rail
Auxiliary powerAC/DC 85–265V or DC 40–60V
Input current50mA / 100mV / 333mV Optional (External Current Sensor Required)
Frequency45–65Hz
Active energy accuracyClass 1
Reactive energy accuracyClass 2
Harmonics accuracy±1% for 2nd–31st Harmonics
Baud rate1200–38400 bps
Working temp.-25°C to +55°C
Humidity≤95% RH, No Condensation

Built-in functions

  • Communication RS485 (Modbus-RTU) Optional Ethernet Communication
  • Modular Design Voltage, Current, Power & Power Factor Phase Angle, Unbalance & Harmonics

DIN-rail mounted. Send us the rated values of your circuit and the supply voltage; we confirm the ordering code, wiring diagram and register list within one working day.


  • Previous:
  • Next:

  • Main technical parameter
    Circuits DIN-rail multi-circuit power meter; accepts the current input of 4 three-phase circuits or 12 single-phase circuits at the same time
    Measured parameters Voltage, current, power, power factor, phase angle, unbalance and harmonics
    Auxiliary power AC/DC 85-265 V or AC 40-60 V; power consumption <=10 VA
    Frequency 45-65 Hz; accuracy 0.05 Hz
    Voltage input Rated AC 3×220/380 V; overload 1.2 times continuous, 2 times for 1 s; power consumption <=0.5 VA per channel
    Current input Secondary rated current 50 mA; overload 1.2 times continuous, 10 times for 1 s; power consumption <=0.5 VA per channel
    Measurement accuracy Voltage and current 0.5 class; active energy 1 class; reactive energy 2 class; 2nd to 31st harmonic +/-1%
    Energy metering Four-quadrant energy, 12-month multi-rate statistics, 31-day freeze, forward and reverse energy
    Tariff setting 4 time zones and 14 time periods
    Demand and extremes Maximum current, maximum power demand, real-time current and power demand; voltage, current and power extremes of the current and previous month
    Alarms Overvoltage, overcurrent, phase failure and DI linkage output
    Event logging 200 loggings recording the actions of DI and DO
    Pulse output Optocoupler pulse with open collector; pulse constant defaults to 400 imp/kWh
    Communication RS485 interface, Modbus-RTU protocol, baud rate 1200-38400
    Switch input 2-way or 4-way passive dry contact with built-in power supply; 2-way active wet node AC220 V to identify generator and mains access
    Switch output Relay normally open contact; contact rating AC 250 V/3 A, DC 30 V/3 A
    Option note Pulse output and active switch input are mutually exclusive; the four passive / two active input set and the two passive / two output set are also alternatives
    Other technical parameter
    Power frequency withstand voltage >AC 2 kV for 1 min
    Insulation resistance Input and output terminals to the chassis >100 MOhm